ISO 9001:2000  

     
         

2200 Series PROTECTION TUBES

With over twenty five years of experience in the specification, design, and manufacture of temperature sensor protection tubes of any configuration, Parker Texas Thermowell consistently outperforms its competitors in customer satisfaction.

Parker maintains an extensive inventory of bar stock, pipe, and flanges that includes 316 SST, 304 SST, 310 SST, 321 SST, 347 SST, 446 SST, carbon steel, Hastelloy, Monel, Inconel, Nickel, Titanium, Stellite 6B, and several other metal grades.

  Company    
     
Quality    
     
Literature    
     
  Contact Us    
       
  Online Quote Request    
             
   
 

ORDERING INFORMATION

 

MANUFACTURING STANDARDS

Material

In compliance with ASTM specifications or other applicable national standard (i.e., ASME, AWS, etc.)

Process Connection

·       Flange:      In compliance with ANSI B16.5 prior to fabrication

·       Bushing:    Welded in place

·       Welded:     Bare tube

Instrument Connection

Male pipe thread in compliance with ANSI B1.20.1-92

 “U” Dimension

±0.50” for immersion lengths <60”

±0.75” for immersion lengths 60” to 96”

±1.00” for immersion lengths >96”

Tip Thickness

¼” ±0.050” (unless otherwise specified)

Welding

Flange to Base Metal:         per TTI Dwg. TX-A1

Bushing to Base Metal:      Fillet weld

Barstock for Closed-end:   per TTI dwg no. TX-FP-TIP(1)

Pipe Cap for Closed-end:  per TTI dwg no. TX-B(1)

(1)    Full penetration weld locations are subject to distortion and internal filler metal slag.

 
TERMINOLOGY

 

Process Connection

External means to connect protection tube to process system. Tubes can be threaded, bolted (to matching flange), or welded in place.

Instrument Connection

Means to connect temperature instrument to protection tube.  Typically male pipe threaded.

“U” Dimension

Length of protection tube immersed into process system. Measured from the base of the process connection to the end tip of the tube.

“H” Dimension

Also called “head length”. Measured from the base of the process connection to the face of the instrument connection.

“S” Dimension

Instrument insertion length into protection tube. Equal to bore length.

“D” Dimension

Outside diameter of protection tube.

Bore Diameter

Inside diameter of protection tube.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
   
   
   
 

6575 Tram Road

Beaumont, Texas   77713

409 924-0300   ♦   409 924-0301 Fax

       
   

©Parker Hannifin Corporation, 2008; All rights reserved